Delta AS Series Operation Manual page 584

Hide thumbs Also See for AS Series:
Table of Contents

Advertisement

Send Quote Requests to info@automatedpt.com
There are devices using the same IP
6012
address.
6100
The email connection is busy.
The trigger attachment mode in the
6103
email is set incorrectly.
The attachment in the email does not
6104
exist.
The attachment in the email is
6105
oversized.
There is an SMTP server response
6106
timeout.
There is an SMTP server response
6107
timeout.
6108
SMTP verification failed
The remote communication IP address
6200
set in the TCP socket function is illegal.
The local communication port set in the
6201
TCP socket function is illegal.
The remote communication port set in
6202
the TCP socket function is illegal.
The device from which the data is sent
6203
in the TCP socket function is illegal.
1. Check if there are devices using the same IP
address.
2. Check if there is more than 1 DHCP or BOOTP
server on the network.
Retry the email connection later. This error does
not cause the PLC to stop running. Solve the
problem by means of the related flag in the
program.
Set up the trigger attachment mode in HWCONFIG
> CPU Module > Device Setting > Options >
Ethernet Port Advanced > Email > Trigger Setting
> Trigger Attachment Mode.
Check whether the attachment exists in the
memory card.
Check the size of the attachment. If the size is over
2 MB, the file cannot be sent as an attachment.
Check for the correct address and set up the
SMTP server in HWCONFIG > CPU Module >
Device Setting > Options > Ethernet Port
Advanced > Email again.
1. Check whether the status of the SMTP server is
normal.
2. Retry sending of the email later. This error does
not cause the PLC to stop running. Solve the
problem by means of the related flag in the
program.
Check for the correct ID/Password and set up in
HWCONFIG > CPU Module > Device Setting >
Options > Ethernet Port Advanced > Email again.
1. Check the program and the related special data
registers.
2. Set the Ethernet parameter for the CPU module
in HWCONFIG CPU Module > Device Setting >
Options > Ethernet Port Advanced > TCP
Socket.
1. Check the program and the related special data
registers.
2. Set the Ethernet parameter for the CPU module
in HWCONFIG CPU Module > Device Setting >
Options > Ethernet Port Advanced > TCP
Socket.
1. Check the program and the related special data
registers.
2. Set the Ethernet parameter for the CPU module
in HWCONFIG CPU Module > Device Setting >
Options > Ethernet Port Advanced > TCP
Socket.
1. Check the program and the related special data
registers.
2. Set the Ethernet parameter for the CPU module
in HWCONFIG CPU Module > Device Setting >
Options > Ethernet Port Advanced > TCP
Socket.
Send Quote Requests to info@automatedpt.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
SM1101
V
SM1113
X
SM1113
X
SM1113
X
SM1113
X
SM1113
X
SM1113
X
SM1113
X
-
X
-
X
-
X
-
X

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents