4.12

4.12.1 Wiring AS02LC-A

Co nne c t the te rm in al
t o th e groun d te rm ina l
Multiple load cells connected to one load cell module:
*1. Connect the
Use the system ground as the third grounding or connect it to the control box.
*2. When connecting multiple load cells, the total resistance of the load cells should be greater than 40 Ω.

Load Cell Modules

4-w ire
6-wi re
S y s t em gr oun d
T he 3rd gro und in g
(g roun d res is ta nc e of
le s s tha n 100 Ω)
of the power module and the
Send Quote Requests to info@automatedpt.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
AS02LC
CH1
CH2
of the load cell module to the system ground terminal.
Converter
Load Cell
Load Cell
Load Cell
Load Cell
Load Cell
Load Cell
Load Cell
Load Cell

Hide quick links: