Delta AS Series Operation Manual page 88

Hide thumbs Also See for AS Series:
Table of Contents

Advertisement

Send Quote Requests to info@automatedpt.com
Digital-to-Analog
Conversion
Rated Output Range
Conversion Range
Hardware Output Range
Error Range
(Room Temperature)
Error Range
(Full Temperature Range)
Linearity Error
(Room Temperature)
Linearity Error
(Full Temperature Range)
Hardware Resolution
Permissible Load
Impedance
0–20 mA
K0
~
K32000
-0.2 mA to 20.2 mA
Send Quote Requests to info@automatedpt.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
Current Output
4–20 mA
K0
~
K32000
3.8–20.2 mA
±0.2%
±0.5%
±0.03%
±0.10%
12 bits
≦550 Ω