 Items on the data exchange table:
Name
Item
Enable
Station Address/
IP Address
Local Address
Remote Address
Quantity
Function Button
The number of the block for data exchange.
Selects whether to enable the data exchange table when the data exchange is performed.
The slave station address for the data exchange table. You can set one address for multiple
data exchange tables. It is a station address under the COM1 and COM2 tabs, and an IP
under the Ethernet tab.
The device address range used by the master in the data exchange table
: Input: the data block where the master reads from a slave
: Output: the data block where the master writes to a slave
This is the device address range used by a slave in the data exchange table.
The device range is in hexadecimal if the slave in the data exchange table is a user-defined
Modbus Device.
This is the size of the data exchange table, which is consistent with the result calculated from
the device range.
Send Quote Requests to info@automatedpt.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
Call +1(800)985-6929 To Order or Order Online At Deltaacdrives.com
Description
for the slaves to power-on is less than the master does.
If not, do not select this option.