Code
Description
20-117
Incorrect position of car-
tridge was detected during
horizontal movement of car-
tridge with inject operation.
Or, an unsupported cartridge
may have been inserted.
ODS-D280U/ODS-D280F
Error remedy method
1.
Check the cartridge type.
Note
Use a cartridge conforming to the drive.
2.
Visually check the cartridge.
•
If an abnormality (such as bulge) is
found, do not use the cartridge any lon-
ger and go to step 4) in Measures.
Tip
For how to handle the defective car-
tridge, contact your local Sony Sales
Office/Service Center.
3.
Check the cartridge insertion method, and
then insert the cartridge.
Note
Press the central area of the cartridge when
inserting it.
•
When this error occurs again, go to
step 4) in Measures.
•
When this error no longer occurs, use
the unit as it is.
4.
Insert another cartridge and check whether
this error occurs again.
•
When this error no longer occurs,
check the following.
-
When this error occurs again by
checking shown in step 3) in
Measures, the previous cartridge
may be defective.
Do not use the previous cartridge
any longer.
Tip
For how to handle the defective
cartridge, contact your local So-
ny Sales Office/Service Center.
-
When this error no longer occurs
by checking shown in step 3) in
Measures, use the unit as it is.
•
When this error occurs again, the se-
lect loader assembly may be defective.
Refer to section
"4-10. Select Loader Assembly"
Continued
2-29