1-17.

Flexible Flat Cable and Coaxial Cable

1-17-1.

Disconnecting/Connecting Flexible Flat Cable

Note
• Be very careful not to fold flexible flat cables. Life of flexible flat cable will be significantly shortened if it is
folded.
• Each flexible flat cable has conductive side and insulated side. If the flexible flat cable is connected in the wrong
orientation of the conductive side and the insulated side, the circuit will not function.
• Check that the conductive side of the flexible flat cable is not contaminated.
• Do not open the locking tab excessively at an angle above the value shown in the figure to prevent the connector
from being damaged.
Type A
Locking tab
Connector
Flexible flat cable
Type B
Locking tab
Connector
Flexible flat cable
Type C
Locking tab
90˚
Connector
Disconnecting
1.
Turn off the power.
2.
Slide or lift up the locking tab in the direction of the arrow to unlock and pull out the flexible flat cable.
ODS-D280U/ODS-D280F
90˚
Insulating surface
120˚
Insulating
surface
Flexible flat cable
(Upper and lower both sides
are conductive surface.)
Angle of locking tab and
angle of connecting-disconnecting flexible flat cable
Locking tab
90˚
0˚ to 20˚
Flexible flat cable
Angle of locking tab and
angle of connecting-disconnecting flexible flat cable
Locking tab
120˚
Flexible flat cable
Angle of locking tab and
angle of connecting-disconnecting flexible flat cable
Locking tab
90˚
Flexible flat cable
1-34