Main
Sub
Error
Code
Code
Logger
20
111
○
117
–
118
○
201
○
208
○
211
○
218
○
291
○
298
○
811
○
818
○
901
○
908
○
911
○
918
○
991
○
998
○
C11
○
C17
○
C18
○
C1E
○
D11
○
D17
○
D18
○
D1E
○
F10
○
ODS-D280U/ODS-D280F
Alarm
Alarm
Description
Status
Indica-
tor
Blinking
Cycle
○
0.25 sec.
Horizontal movement of cartridge did not end within the speci-
fied time period with inject operation.
○
1 sec.
Incorrect position of cartridge was detected during horizontal
movement of cartridge with inject operation.
Or, an unsupported cartridge may have been inserted.
○
0.25 sec.
Abnormal current was detected in the loading motor during hor-
izontal movement of cartridge with inject operation.
○
0.25 sec.
Operation of the select arm mechanism did not end within the
specified time period during disc loading operation.
○
0.25 sec.
Abnormal current was detected in the lever motor during disc
loading operation.
○
0.25 sec.
Disc loading operation did not end within the specified time pe-
riod.
○
0.25 sec.
Abnormal current was detected in the carry motor (H) during
disc loading operation.
○
0.25 sec.
Disc chucking operation did not end within the specified time
period.
○
0.25 sec.
Abnormal current was detected in the carry motor (V) during
disc chucking operation.
○
0.25 sec.
Horizontal movement of cartridge did not end within the speci-
fied time period with eject operation.
○
0.25 sec.
Abnormal current was detected in the loading motor during hor-
izontal movement of cartridge with eject operation.
○
0.25 sec.
Operation of the select arm mechanism did not end within the
specified time period during disc unloading operation.
○
0.25 sec.
Abnormal current was detected in the lever motor during disc
unloading operation.
○
0.25 sec.
Disc unloading operation did not end within the specified time
period.
○
0.25 sec.
Abnormal current was detected in the carry motor (H) during
disc unloading operation.
○
0.25 sec.
Disc unchucking operation or disc cartridge loading operation
did not end within the specified period.
○
0.25 sec.
Abnormal current was detected in the carry motor (V) during
disc unchucking operation or disc cartridge loading operation.
○
0.25 sec.
Vertical movement to lower direction of the select mechanism
did not end within the specified time period.
○
0.25 sec.
Incorrect position of cartridge was detected during vertical
movement to lower direction of the select mechanism.
○
0.25 sec.
Abnormal current was detected in the up/down motor during
vertical movement to lower direction of the select mechanism.
○
0.25 sec.
Displacement of standard position was detected during vertical
movement to lower direction of the select mechanism.
○
0.25 sec.
Vertical movement to upper direction of the select mechanism
did not end within the specified time period.
○
0.25 sec.
Incorrect position of cartridge was detected during vertical
movement to upper direction of the select mechanism.
○
0.25 sec.
Abnormal current was detected in the up/down motor during
vertical movement to upper direction of the select mechanism.
○
0.25 sec.
Displacement of standard position was detected during vertical
movement to upper direction of the select mechanism.
○
0.25 sec.
Abnormality was detected in initialization of the loader.
Continued
2-5