Code
Description
06-FC1
The SA actuator of optical
block assembly Ch-1B can-
not detect the reference posi-
tion. (On side 0)
08-091
The spindle motor does not
work (or there is no FG sig-
nal) after the specified time
period has passed.
08-095
The spindle motor cannot be
stopped and continues to ro-
tate (or the FG signal is ab-
normal).
12-020
Optical block assembly
Ch-2A is recording data with
the maximum laser output.
(On side 1)
12-025
Optical block assembly
Ch-2A detected a laser out-
put error. (On side 1)
ODS-D280U/ODS-D280F
Error remedy method
1.
Eject a cartridge.
2.
Startup the maintenance menu and perform
SA ACTUATOR.
•
When no error occurs, use the unit as
it is.
•
When an error occurs, go to step 3) in
Measures.
3.
Check the flexible flat cable connection be-
tween the main base assembly and the
DR-683 board.
If this problem still remains, the optical block as-
sembly (OP-1) or the DR-683 board may be de-
fective.
1.
Eject a cartridge.
2.
Startup the maintenance menu and perform
SPINDLE MOTOR AUTO TEST.
•
When no error occurs, use the unit as
it is.
•
When an error occurs, go to step 3) in
Measures.
3.
Check the carry loader assembly installation
status.
4.
Check the flexible flat cable connection be-
tween the main base assembly and the
DR-683 board.
If this problem still remains, the spindle motor or
the DR-683 board may be defective
1.
Eject a cartridge.
2.
Startup the maintenance menu and perform
SPINDLE MOTOR AUTO TEST.
•
When no error occurs, use the unit as
it is.
•
When an error occurs, go to step 3) in
Measures.
3.
Check the flexible flat cable connection be-
tween the main base assembly and the
DR-683 board.
If this problem still remains, the spindle motor or
the DR-683 board may be defective.
1.
Eject a cartridge.
2.
Check laser parameter 2 of hours meter.
When laser parameter 2 of hours meter has:
•
not reached the end of replacement cy-
cle:
There is something wrong with the op-
tical or electrical system in optical
block assembly (OP-2).
•
reached the end of replacement cycle:
It is likely laser in optical block as-
sembly (OP-2) reached to the end of its
life cycle.
3.
Replace optical block assembly (OP-2).
1.
Eject a cartridge.
2.
Check laser parameter 2 of hours meter.
When laser parameter 2 of hours meter has:
•
not reached the end of replacement cy-
cle:
There is something wrong with the op-
tical or electrical system in optical
block assembly (OP-2).
•
reached the end of replacement cycle:
It is likely laser in optical block as-
sembly (OP-2) reached to the end of its
life cycle.
3.
Replace optical block assembly (OP-2).
Refer to section
"4-30. Main Base Assembly"
"6-4-8. SA ACTUATOR"
"4-11. Carry Loader Assembly"
"4-30. Main Base Assembly"
"6-4-7. SPINDLE MOTOR AU-
TO TEST"
"4-30. Main Base Assembly"
"6-4-7. SPINDLE MOTOR AU-
TO TEST"
"3-1. Periodic Inspection"
"4-29. Sub Base Assembly"
"5. Adjustment of Optical Drive
System"
"3-1. Periodic Inspection"
"4-29. Sub Base Assembly"
"5. Adjustment of Optical Drive
System"
Continued
2-21