Sony ODS-D280U Service Manual page 64

Optical disc archive drive unit
Hide thumbs Also See for ODS-D280U:
Table of Contents

Advertisement

Code
Description
02-0A5
Optical block assembly
Ch-0B detected a laser out-
put error. (On side 0)
02-0A7
Laser drive overcurrent was
detected in optical block as-
sembly Ch-0B. (On side 0)
02-120
Optical block assembly
Ch-1A is recording data with
the maximum laser output.
(On side 0)
02-125
Optical block assembly
Ch-1A detected a laser out-
put error. (On side 0)
02-127
Laser drive overcurrent was
detected in optical block as-
sembly Ch-1A. (On side 0)
ODS-D280U/ODS-D280F
Error remedy method
1.
Eject a cartridge.
2.
Check laser parameter 0 of hours meter.
When laser parameter 0 of hours meter has:
not reached the end of replacement cy-
cle:
There is something wrong with the op-
tical or electrical system in optical
block assembly (OP-0).
reached the end of replacement cycle:
It is likely laser in optical block as-
sembly (OP-0) reached to the end of its
life cycle.
3.
Replace optical block assembly (OP-0).
1.
Eject a cartridge.
2.
Check laser parameter 0 of hours meter.
When laser parameter 0 of hours meter has:
not reached the end of replacement cy-
cle:
There is something wrong with the op-
tical or electrical system in optical
block assembly (OP-0).
reached the end of replacement cycle:
It is likely laser in optical block as-
sembly (OP-0) reached to the end of its
life cycle.
3.
Replace optical block assembly (OP-0).
1.
Eject a cartridge.
2.
Check laser parameter 1 of hours meter.
When laser parameter 1 of hours meter has:
not reached the end of replacement cy-
cle:
There is something wrong with the op-
tical or electrical system in optical
block assembly (OP-1).
reached the end of replacement cycle:
It is likely laser in optical block as-
sembly (OP-1) reached to the end of its
life cycle.
3.
Replace optical block assembly (OP-1).
1.
Eject a cartridge.
2.
Check laser parameter 1 of hours meter.
When laser parameter 1 of hours meter has:
not reached the end of replacement cy-
cle:
There is something wrong with the op-
tical or electrical system in optical
block assembly (OP-1).
reached the end of replacement cycle:
It is likely laser in optical block as-
sembly (OP-1) reached to the end of its
life cycle.
3.
Replace optical block assembly (OP-1).
1.
Eject a cartridge.
2.
Check laser parameter 1 of hours meter.
When laser parameter 1 of hours meter has:
not reached the end of replacement cy-
cle:
There is something wrong with the op-
tical or electrical system in optical
block assembly (OP-1).
reached the end of replacement cycle:
It is likely laser in optical block as-
sembly (OP-1) reached to the end of its
life cycle.
3.
Replace optical block assembly (OP-1).
Refer to section
"3-1. Periodic Inspection"
"4-30. Main Base Assembly"
"5. Adjustment of Optical Drive
System"
"3-1. Periodic Inspection"
"4-30. Main Base Assembly"
"5. Adjustment of Optical Drive
System"
"3-1. Periodic Inspection"
"4-30. Main Base Assembly"
"5. Adjustment of Optical Drive
System"
"3-1. Periodic Inspection"
"4-30. Main Base Assembly"
"5. Adjustment of Optical Drive
System"
"3-1. Periodic Inspection"
"4-30. Main Base Assembly"
"5. Adjustment of Optical Drive
System"
Continued
2-16

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ods-d280f

Table of Contents