Sony ODS-D280U Service Manual page 74

Optical disc archive drive unit
Hide thumbs Also See for ODS-D280U:
Table of Contents

Advertisement

Code
Description
13-1D4
A signal from the disc re-
quired for focus servo of op-
tical block assembly Ch-3B
cannot be detected. (On side
1)
14-07C
Optical block assembly
OP-2 cannot move to the in-
nermost circumference of
the disc. (On side 1)
14-17C
Optical block assembly
OP-3 cannot move to the in-
nermost circumference of
the disc. (On side 1)
16-E41
The SA actuator of optical
block assembly Ch-2A can-
not detect the reference posi-
tion. (On side 1)
ODS-D280U/ODS-D280F
Error remedy method
1.
Eject a cartridge.
2.
Insert again the ejected cartridge.
When no error occurs, use the unit as
it is.
When an error occurs, go to step 3) in
Measures.
3.
Insert another cartridge.
In the case no error occurs:
The ejected cartridge is likely to be
faulty.
In the case the error occurs:
Drive trouble is likely.
4.
Check the carry loader assembly installation
status.
Note
If the carry loader assembly is abnormally
installed, disc chucking is not performed
successfully and focus servo may fail.
1.
Eject a cartridge.
2.
Startup the maintenance menu and perform
SLIDER AUTO TEST.
When no error occurs, use the unit as
it is.
When an error occurs, go to step 3) in
sub
Measures.
3.
Check the main base assembly installation
status and the carry loader assembly instal-
lation status.
4.
Check the flexible flat cable connection be-
tween the sub base assembly and the DR-683
board.
If this problem still remains, any abnormality may
be present in the slider of the optical block assem-
bly (OP-2) or the DR-683 board may be defective.
1.
Eject a cartridge.
2.
Startup the maintenance menu and perform
SLIDER AUTO TEST.
When no error occurs, use the unit as
it is.
When an error occurs, go to step 3) in
sub
Measures.
3.
Check the main base assembly installation
status and the carry loader assembly instal-
lation status.
4.
Check the flexible flat cable connection be-
tween the sub base assembly and the DR-683
board.
If this problem still remains, any abnormality may
be present in the slider of the optical block assem-
bly (OP-3) or the DR-683 board may be defective.
1.
Eject a cartridge.
2.
Startup the maintenance menu and perform
SA ACTUATOR.
When no error occurs, use the unit as
it is.
When an error occurs, go to step 3) in
Measures.
3.
Check the flexible flat cable connection be-
tween the sub base assembly and the DR-683
board.
If this problem still remains, the optical block as-
sembly (OP-2) or the DR-683 board may be de-
fective.
Refer to section
"3-1. Periodic Inspection"
"4-11. Carry Loader Assembly"
"4-29. Sub Base Assembly"
"5. Adjustment of Optical Drive
System"
"4-11. Carry Loader Assembly"
"4-29. Sub Base Assembly"
"6-4-6. SLIDER AUTO TEST"
"4-11. Carry Loader Assembly"
"4-29. Sub Base Assembly"
"6-4-6. SLIDER AUTO TEST"
"4-29. Sub Base Assembly"
"6-4-8. SA ACTUATOR"
Continued