Main
Sub
Error
Code
Code
Logger
0A7
○
120
○
125
○
127
○
1A0
○
1A5
○
1A7
○
820
○
8A0
○
920
○
9A0
○
03
054
○
0D4
○
154
○
1D4
○
04
07C
○
17C
○
06
E41
○
EC1
○
F41
○
FC1
○
08
091
○
095
○
12
020
○
025
○
027
○
ODS-D280U/ODS-D280F
Alarm
Alarm
Description
Status
Indica-
tor
Blinking
Cycle
○
0.25 sec.
Laser drive overcurrent was detected in optical block assembly
Ch-0B. (On side 0)
○
0.25 sec.
Optical block assembly Ch-1A is recording data with the max-
imum laser output. (On side 0)
○
0.25 sec.
Optical block assembly Ch-1A detected a laser output error. (On
side 0)
○
0.25 sec.
Laser drive overcurrent was detected in optical block assembly
Ch-1A. (On side 0)
○
0.25 sec.
Optical block assembly Ch-1B is recording data with the maxi-
mum laser output. (On side 0)
○
0.25 sec.
Optical block assembly Ch-1B detected a laser output error. (On
side 0)
○
0.25 sec.
Laser drive overcurrent was detected in optical block assembly
Ch-1B. (On side 0)
○
0.25 sec.
Data was played with the maximum laser output in optical block
assembly Ch-0A. (On side 0)
○
0.25 sec.
Data was played with the maximum laser output in optical block
assembly Ch-0B. (On side 0)
○
0.25 sec.
Data was played with the maximum laser output in optical block
assembly Ch-1A. (On side 0)
○
0.25 sec.
Data was played with the maximum laser output in optical block
assembly Ch-1B. (On side 0)
○
0.25 sec.
A signal from the disc required for focus servo of optical block
assembly Ch-0A cannot be detected. (On side 0)
○
0.25 sec.
A signal from the disc required for focus servo of optical block
assembly Ch-0B cannot be detected. (On side 0)
○
0.25 sec.
A signal from the disc required for focus servo of optical block
assembly Ch-1A cannot be detected. (On side 0)
○
0.25 sec.
A signal from the disc required for focus servo of optical block
assembly Ch-1B cannot be detected. (On side 0)
○
0.25 sec.
Optical block assembly OP-0 cannot move to the innermost cir-
cumference of the disc. (On side 0)
○
0.25 sec.
Optical block assembly OP-1 cannot move to the innermost cir-
cumference of the disc. (On side 0)
○
0.25 sec.
The SA actuator of optical block assembly Ch-0A cannot detect
the reference position. (On side 0)
○
0.25 sec.
The SA actuator of optical block assembly Ch-0B cannot detect
the reference position. (On side 0)
○
0.25 sec.
The SA actuator of optical block assembly Ch-1A cannot detect
the reference position. (On side 0)
○
0.25 sec.
The SA actuator of optical block assembly Ch-1B cannot detect
the reference position. (On side 0)
○
0.25 sec.
The spindle motor does not work (or there is no FG signal) after
the specified time period has passed.
○
0.25 sec.
The spindle motor cannot be stopped and continues to rotate (or
the FG signal is abnormal).
○
0.25 sec.
Optical block assembly Ch-2A is recording data with the max-
imum laser output. (On side 1)
○
0.25 sec.
Optical block assembly Ch-2A detected a laser output error. (On
side 1)
○
0.25 sec.
Laser drive overcurrent was detected in optical block assembly
Ch-2A. (On side 1)
Continued
2-3