7.
Rotate the worm gear in the counterclockwise direction using the screwdriver to move the SE rail plate to the
position shown in the illustration.
Check that the tip of the SE REC INHI
switch arm is lowered to the position
shown in the illustration.
Note
When rotating the worm gear using the screwdriver, be careful not to cause the tooth skipping of the gear due to
excessive rotation.
The SE rail plate is pulled by the spring. If a force in the direction opposite to the worm wheel is applied to the tip
of the worm gear, the tooth skipping of the gear may easily occur. Therefore, carefully rotate the worm gear.
ODS-D280U/ODS-D280F
SE elevate rail
Worm gear
SE rail plate
Front side
Screwdriver
1-24