Code
Description
92-5B5
Communication between
Disc Drive LSI 3a (Base
Drive) and BRIDGE (IC700
internal: BI-353 (ODS-
D280U)/BF-92 (ODS-
D280F) board) cannot be es-
tablished during startup. (On
side 1)
92-5B7
Failure in Disc Drive LSI 3a
(Base Drive) firmware up-
grade was detected during
startup. (On side 1)
92-5C5
Communication between
Disc Drive LSI 3b (Base
Drive) and BRIDGE (IC700
internal: BI-353 (ODS-
D280U)/BF-92 (ODS-
D280F) board) cannot be es-
tablished during startup. (On
side 1))
92-5C7
Failure in Disc Drive LSI 3b
(Base Drive) firmware up-
grade was detected during
startup. (On side 1)
92-695
Communication between
SYCPU (IC700 internal:
BI-353 (ODS-D280U)/
BF-92 (ODS-D280F) board)
and 2a (Base Drive) cannot
be established during startup.
Or, failure in 2a (Base Drive)
firmware upgrade was detec-
ted during startup. (On side
1)
92-6A5
Communication between
SYCPU (IC700 internal:
BI-353 (ODS-D280U)/
BF-92 (ODS-D280F) board)
and 2b (Base Drive) cannot
be established during startup.
Or, failure in 2b (Base Drive)
firmware upgrade was detec-
ted during startup. (On side
1)
92-6B5
Communication between
SYCPU (IC700 internal:
BI-353 (ODS-D280U)/
BF-92 (ODS-D280F) board)
and 3a (Base Drive) cannot
be established during startup.
Or, failure in 3a (Base Drive)
firmware upgrade was detec-
ted during startup. (On side
1)
ODS-D280U/ODS-D280F
Error remedy method
When the sub base assembly or the DR-683
board or the BI-353 board (ODS-D280U)/
BF-92 board (ODS-D280F) has been re-
placed:
Check the installation status.
When this error occurs after firmware up-
grade:
Turn off and on the drive, and then upgrade
the firmware again.
Turn off and on the drive, and then upgrade the
firmware again.
Note
If the drive is turned off during firmware upgrade,
the firmware upgrade may fail.
If the same phenomenon occurs again, the
drive may be defective.
When the sub base assembly or the DR-683
board or the BI-353 board (ODS-D280U)/
BF-92 board (ODS-D280F) has been re-
placed:
Check the installation status.
When this error occurs after firmware up-
grade:
Turn off and on the drive, and then upgrade
the firmware again.
Turn off and on the drive, and then upgrade the
firmware again.
Note
If the drive is turned off during firmware upgrade,
the firmware upgrade may fail.
If the same phenomenon occurs again, the
drive may be defective.
When the sub base assembly or the DR-683
board or the BI-353 board (ODS-D280U)/
BF-92 board (ODS-D280F) has been re-
placed:
Check the installation status.
When this error occurs after firmware up-
grade:
Turn off and on the drive, and then upgrade
the firmware again.
When the sub base assembly or the DR-683
board or the BI-353 board (ODS-D280U)/
BF-92 board (ODS-D280F) has been re-
placed:
Check the installation status.
When this error occurs after firmware up-
grade:
Turn off and on the drive, and then upgrade
the firmware again.
When the sub base assembly or the DR-683
board or the BI-353 board (ODS-D280U)/
BF-92 board (ODS-D280F) has been re-
placed:
Check the installation status.
When this error occurs after firmware up-
grade:
Turn off and on the drive, and then upgrade
the firmware again.
Refer to section
"1-8. Location of Main Parts"
"1-14. Cautions on Handling the
Optical Block Assembly"
"1-16. Service Action after Re-
placing Blocks and Mounted
Boards"
"4-19. BI-353/BF-92 Board"
"4-29. Sub Base Assembly"
"7. Firmware Upgrade"
"7. Firmware Upgrade"
"1-8. Location of Main Parts"
"1-14. Cautions on Handling the
Optical Block Assembly"
"1-16. Service Action after Re-
placing Blocks and Mounted
Boards"
"4-19. BI-353/BF-92 Board"
"4-29. Sub Base Assembly"
"7. Firmware Upgrade"
"7. Firmware Upgrade"
"1-8. Location of Main Parts"
"1-14. Cautions on Handling the
Optical Block Assembly"
"1-16. Service Action after Re-
placing Blocks and Mounted
Boards"
"4-19. BI-353/BF-92 Board"
"4-29. Sub Base Assembly"
"7. Firmware Upgrade"
"1-8. Location of Main Parts"
"1-14. Cautions on Handling the
Optical Block Assembly"
"1-16. Service Action after Re-
placing Blocks and Mounted
Boards"
"4-19. BI-353/BF-92 Board"
"4-29. Sub Base Assembly"
"7. Firmware Upgrade"
"1-8. Location of Main Parts"
"1-14. Cautions on Handling the
Optical Block Assembly"
"1-16. Service Action after Re-
placing Blocks and Mounted
Boards"
"4-19. BI-353/BF-92 Board"
"4-29. Sub Base Assembly"
"7. Firmware Upgrade"
Continued
2-71

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ods-d280f

Table of Contents