Code
Description
37-901
The temperature sensor of
the optical block assembly
Ch-0A detected a value equal
to or greater than the opera-
tion limit temperature. (On
side 0)
37-A01
The temperature sensor of
the optical block assembly
Ch-0B detected a value equal
to or greater than the opera-
tion limit temperature. (On
side 0)
ODS-D280U/ODS-D280F
Error remedy method
1.
Eject the cartridge.
2.
Check whether there is any obstacle that
blocks air flow from the fan exhaust outlet
and to the air vents (front/rear).
3.
Check the ambient temperature of this unit.
4.
Startup the maintenance menu and perform
FAN MOTOR.
When this operation fails, check the instal-
lation of the relevant fan and the cable con-
nection.
Improper connection (half insertion or
oblique insertion)
Damage to connectors
Significant scratches or disconnection
of flexible flat cables
Damage or contamination at connect-
ing parts (Unplug flexible flat cables.)
5.
Check the installation status of the heatsink
on the BI-353 board (ODS-D280U) /BF-92
board (ODS-D280F).
6.
Check the air filter.
If the air filter is significantly conta-
minated, replace it.
1.
Eject the cartridge.
2.
Check whether there is any obstacle that
blocks air flow from the fan exhaust outlet
and to the air vents (front/rear).
3.
Check the ambient temperature of this unit.
4.
Startup the maintenance menu and perform
FAN MOTOR.
When this operation fails, check the instal-
lation of the relevant fan and the cable con-
nection.
Improper connection (half insertion or
oblique insertion)
Damage to connectors
Significant scratches or disconnection
of flexible flat cables
Damage or contamination at connect-
ing parts (Unplug flexible flat cables.)
5.
Check the installation status of the heatsink
on the BI-353 board (ODS-D280U) /BF-92
board (ODS-D280F).
6.
Check the air filter.
If the air filter is significantly conta-
minated, replace it.
Refer to section
"1-9. Location of Sensors and
Their Functions"
"3-2-5. Cleaning after Operation
in Special Environment"
"4-9. Fan 40 Assembly (RP) and
Fan 60 Assembly (RP)"
"4-19. BI-353/BF-92 Board"
"4-26. Air Filter"
"6-4-2. FAN MOTOR"
"1-9. Location of Sensors and
Their Functions"
"3-2-5. Cleaning after Operation
in Special Environment"
"4-9. Fan 40 Assembly (RP) and
Fan 60 Assembly (RP)"
"4-19. BI-353/BF-92 Board"
"4-26. Air Filter"
"6-4-2. FAN MOTOR"
Continued
2-53

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ods-d280f

Table of Contents