2.
Disconnect the harnesses and cables.
(1) Disconnect the two harnesses from the connectors (CN45 and CN195) on the BF-92 board.
(2) Disconnect the two flexible flat cables from the connectors (CN48 and CN683) on the BF-92 board.
(3) Disconnect the flexible wiring board from the connector (CN61) on the BF-92 board.
(4) Disconnect the two fine-wire coaxial cables from the connectors (CN400 and CN401) on the BF-92 board.
Notes on installation
Fine-wire coaxial
cable (short)
Tape AS
BF-92 board
Fine-wire coaxial
cable (long)
n
Be careful that the fine-wire coaxial cables do
not ride on the connectors and chip parts.
Flexible flat cable
ODS-D280U/ODS-D280F
Tape AS 1/2
Connector
Connected
from CA lower
BU assembly
Connector
Connected from
CA upper BU
assembly
CN48
CN400
Tape AS
Fine-fire
coaxial cables
CN683
CN45
CN401
CN195
Tape AS 1/2
Harness
Flexible flat cable
Flexible wiring board
CN61
Harness
BF-92 board
Rear side
Upper side
4-50