3.
Insert the working cartridge and the click the [SET] button.
The loading of the working cartridge starts.
SWITCH
LOADING...--->..
LID OPEN:OPEN
REC INHI:NOT INHI
EXIT: MENU KEY
Tip
The item of "REC INHI" may change during practice.
4.
The setting of the recording inhibition tab of the working cartridge and the state of door open/close are displayed.
• When recording is enabled by the setting on the tab
SWITCH
LOADING...COMPLETED
LID OPEN:CLOSE
REC INHI:NOT INHI
EXIT: MENU KEY
• When recording is inhibited by the setting on the tab
SWITCH
LOADING...COMPLETED
LID OPEN:CLOSE
REC INHI:INHI
EXIT: MENU KEY
When recording is inhibited by the setting on the tab and "REC INHI: NOT INHI" (recordable state) is indicated or
when recording is enabled by the setting on the tab and "REC INHI: INHI" (unrecordable state) is indicated, the following
problems are considered.
• REC INH switch (S1: SM-48 board) is defective.
• Flexible flat cable connection between the SM-48 board and the BF-92 board (ODS-D280F)/BI-353 board (ODS-
D280U) is defective.
When "OPEN" is indicated with the door closed, the following problems are considered.
• LID OPEN sensor (PH2: SM-49 board) is defective.
• Flexible flat cable connection between the SM-49 board and the SM-48 board is defective.
Note
When a door is open at the time of check completion, abnormality is thought about for the installation of the door. Check
whether a door is attached definitely. (Refer to
ODS-D280U/ODS-D280F
"4-6. FR Front Block
Assembly")