Sony ODS-D280U Service Manual page 133

Optical disc archive drive unit
Hide thumbs Also See for ODS-D280U:
Table of Contents

Advertisement

Code
Description
96-B60
A system error was detected
in Disc Drive LSI 3a (Base
Drive). (On side 1)
96-B61
A servo firmware communi-
cation error was detected in
Disc Drive LSI 3a (Base
Drive). (On side 1)
96-C07
Head data cannot be read
from the EEPROM in optical
block assembly Ch-3B. (On
side 1)
96-C0A
A mismatch of OP ID was
detected in the hours meter
data on the Ch-3B side and
the EEPROM data of the op-
tical block assembly Ch-3B.
(On side 1)
96-C30
There is no response from the
optical block assembly
Ch-3B. (On side 1)
96-C42
Disc Drive LSI 3b (Base
Drive) cannot write data to
the FLASH (Base Drive).
(On side 1)
*1:
For the ODS-D280F, perform "Eject" operation from the PC (or host device) or press the EJECT button on the rear of the drive to eject
the cartridge.
Note
EJECT button operation or power off/on operation may generate another alarm code.
ODS-D280U/ODS-D280F
Error remedy method
1.
Acquire the drive/driver log.
2.
Turn off and on the power.
3.
*1
Eject a cartridge.
If the cartridge is not ejected, take the fol-
lowing measures.
Turn off and on the drive. Press the
EJECT button after startup to eject the
cartridge.
If the cartridge is not ejected even after
this operation, eject it manually.
4.
Insert the same cartridge.
If the cartridge cannot be inserted, turn
off and on the drive and then insert the
cartridge again.
If this error occurs again, take the fol-
lowing actions.
5.
When parts have been replaced, check their
installation status.
6.
Upgrade the drive firmware to the latest ver-
sion.
If the same error occurs repeatedly,
send the acquired drive/driver log to
your local Sony Sales Office/Service
Center.
1.
Eject a cartridge.
2.
Acquire the drive/driver log.
3.
Turn off the drive.
4.
Turn on the drive and insert the same car-
tridge.
When no error occurs, use the unit as
it is
When an error occurs, the drive may
be defective.
1.
After the sub base assembly is replaced, take
necessary actions.
2.
Check the sub base assembly installation sta-
tus.
1.
After the sub base assembly is replaced, take
necessary actions.
2.
Check the sub base assembly installation sta-
tus.
1.
After the sub base assembly is replaced, take
necessary actions.
2.
Check the sub base assembly installation sta-
tus.
1.
After the sub base assembly is replaced, take
necessary actions.
2.
Check the sub base assembly installation sta-
tus.
Refer to section
"1-8. Location of Main Parts"
"1-10. How to Eject the Car-
tridge (ODS-D280F)"
"1-11. How to Eject the Car-
tridge Manually"
"7. Firmware Upgrade"
"1-16. Service Action after Re-
placing Blocks and Mounted
Boards"
"4-29. Sub Base Assembly"
"5. Adjustment of Optical Drive
System"
"1-16. Service Action after Re-
placing Blocks and Mounted
Boards"
"4-29. Sub Base Assembly"
"5. Adjustment of Optical Drive
System"
"1-16. Service Action after Re-
placing Blocks and Mounted
Boards"
"4-29. Sub Base Assembly"
"5. Adjustment of Optical Drive
System"
"1-16. Service Action after Re-
placing Blocks and Mounted
Boards"
"4-29. Sub Base Assembly"
"5. Adjustment of Optical Drive
System"
Continued
2-85