Code
Description
92-6C5
Communication between
SYCPU (IC700 internal:
BI-353 (ODS-D280U)/
BF-92 (ODS-D280F) board)
and 3b (Base Drive) cannot
be established during startup.
Or, failure in 3b (Base Drive)
firmware upgrade was detec-
ted during startup. (On side
1)
A firmware error of Disc
92-99F
Failure in Disc Drive LSI 2a
Drive LSI 2a (Base Drive)
(Base Drive) firmware up-
was detected. (On side 1)
grade was detected during
startup. (On side 1)
92-AAF
A firmware error of Disc
Failure in Disc Drive LSI 2b
Drive LSI 2b (Base Drive)
(Base Drive) firmware up-
was detected. (On side 1)
grade was detected during
startup. (On side 1)
92-BBF
A firmware error of Disc
Failure in Disc Drive LSI 3a
Drive LSI 3a (Base Drive)
(Base Drive) firmware up-
was detected. (On side 1)
grade was detected during
startup. (On side 1)
A firmware error of Disc
92-CCF
Failure in Disc Drive LSI 3b
Drive LSI 3b (Base Drive)
(Base Drive) firmware up-
was detected. (On side 1)
grade was detected during
startup. (On side 1)
ODS-D280U/ODS-D280F
Error remedy method
•
When the sub base assembly or the DR-683
board or the BI-353 board (ODS-D280U)/
BF-92 board (ODS-D280F) has been re-
placed:
Check the installation status.
•
When this error occurs after firmware up-
grade:
Turn off and on the drive, and then upgrade
the firmware again.
Turn off and on the drive power, and then perform
again firmware update.
•
The drive power may have been shut down
during firmware update.
If the same error persists, a drive malfunction
is likely.
Turn off and on the drive power, and then perform
again firmware update.
•
The drive power may have been shut down
during firmware update.
If the same error persists, a drive malfunction
is likely.
Turn off and on the drive power, and then perform
again firmware update.
•
The drive power may have been shut down
during firmware update.
If the same error persists, a drive malfunction
is likely.
Turn off and on the drive power, and then perform
again firmware update.
•
The drive power may have been shut down
during firmware update.
If the same error persists, a drive malfunction
is likely.
Refer to section
"1-8. Location of Main Parts"
"1-14. Cautions on Handling the
Optical Block Assembly"
"1-16. Service Action after Re-
placing Blocks and Mounted
Boards"
"4-19. BI-353/BF-92 Board"
"4-29. Sub Base Assembly"
"7. Firmware Upgrade"
"7. Firmware Upgrade"
"7. Firmware Upgrade"
"7. Firmware Upgrade"
"7. Firmware Upgrade"
2-72