Without A Lift - Juniper SRX5400 Hardware Manual

Services gateway
Hide thumbs Also See for SRX5400:
Table of Contents

Advertisement

SRX5400 Services Gateway Hardware Guide
Tools Required to Install the SRX5400 Services Gateway Without a Mechanical Lift
Related
Documentation
Removing Components from the SRX5400 Chassis Before Installing It Without a Lift
Removing the Power Supplies Before Installing the SRX5400 Services Gateway Without a Lift
212
To install the services gateway, you need the following tools and parts:
Phillips (+) screwdrivers, numbers 1 and 2
7/16-in. (11 mm) nut driver
ESD grounding wrist strap
Overview of Installing the SRX5400 Services Gateway Without a Mechanical Lift on
page 211
Removing Components from the SRX5400 Chassis Before Installing It Without a Lift
on page 212
Installing the SRX5400 Services Gateway Chassis in the Rack Manually on page 216
Reinstalling Components in the SRX5400 Services Gateway Chassis After Installing
It Without a Lift on page 218
If you cannot use a mechanical lift to install the services gateway (the preferred method),
you can install it manually. Before installing the services gateway manually, you must
first remove components from the chassis, and reinstall the components the chassis is
installed in the rack. With components removed, the chassis weighs approximately 65 lb
(29 kg).
Removing the Power Supplies Before Installing the SRX5400 Services Gateway
1.
Without a Lift on page 212
Removing the Fan Tray Before Installing an SRX5400 Services Gateway Without a
2.
Lift on page 213
Removing Cards Before Installing an SRX5400 Services Gateway Without a
3.
Lift on page 214
Remove the leftmost power supply first and then work your way to the right. To remove
the AC or DC power supplies for each power supply (see
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect
1.
the strap to one of the ESD points on the chassis.
On an AC-powered services gateway, switch the AC input switch on each power supply
2.
to the off (
O
) position. On a DC-powered services gateway, Move the DC circuit breaker
on each DC power supply to the off (
We recommend this even though the power supplies are not connected to power
sources.
Figure 71 on page
) position.
O
Copyright © 2014, Juniper Networks, Inc.
213):

Advertisement

Table of Contents
loading

Table of Contents