Connecting An Srx5400 Services Gateway Ac Power Supply Cord; Replacing An Srx5400 Services Gateway Dc Power Supply Cable; Disconnecting An Srx5400 Services Gateway Dc Power Supply Cable - Juniper SRX5400 Hardware Manual

Services gateway
Hide thumbs Also See for SRX5400:
Table of Contents

Advertisement

SRX5400 Services Gateway Hardware Guide

Connecting an SRX5400 Services Gateway AC Power Supply Cord

Related
Documentation

Replacing an SRX5400 Services Gateway DC Power Supply Cable

Disconnecting an SRX5400 Services Gateway DC Power Supply Cable

144
To connect the AC power cord:
Locate a replacement power cord with the type of plug appropriate for your
1.
geographical location.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect
2.
the strap to one of the ESD points on the chassis.
Insert the power cord plug into an external AC power source receptacle.
3.
Connect the power cord to the power supply.
4.
Route the power cord along the cable restraint toward the left or right corner of the
5.
chassis. If needed to hold the power cord in place, thread plastic cable ties, which you
must provide, through the openings on the cable restraint.
Verify that the power cord does not block the air exhaust and access to services
6.
gateway components, or drape where people could trip on it.
Switch the AC switch on the each power supply to the on position (
7.
the status LEDs on the power supply faceplate. If the power supply is correctly installed
and functioning normally, the
LED is not lit.
SRX5400 Services Gateway AC Power Supply on page 24
SRX5400 Services Gateway AC Power Supply LEDs on page 25
Replacing an SRX5400 Services Gateway AC Power Supply on page 137
SRX5400 Services Gateway AC Power Supply Specifications on page 194
To replace an SRX5400 Services Gateway DC power supply cable, perform the following
procedures:
Disconnecting an SRX5400 Services Gateway DC Power Supply Cable on page 144
1.
Connecting an SRX5400 Services Gateway DC Power Supply Cable on page 145
2.
To remove a power cable from a DC power supply:
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist and connect
1.
the strap to an approved site ESD grounding point.
Switch off the external circuit breakers for all the cables attached to the power supply.
2.
Make sure that the voltage across the DC power source cable leads is 0 V and that
there is no chance that the cables might become active during the removal process.
Remove the power cable from the DC power source.
3.
and
LEDs light steadily, and the
AC OK
DC OK
Copyright © 2014, Juniper Networks, Inc.
) and observe
PS FAIL

Advertisement

Table of Contents
loading

Table of Contents