Replacing An Srx5400 Services Gateway Network Cable - Juniper SRX5400 Hardware Manual

Services gateway
Hide thumbs Also See for SRX5400:
Table of Contents

Advertisement

Related
Documentation

Replacing an SRX5400 Services Gateway Network Cable

Copyright © 2014, Juniper Networks, Inc.
PIC 2
Online
PIC 3
Online
Slot 2
Online
PIC 0
Online
PIC 2
Online
Issue the show chassis cluster status command to make sure that the priority for all
11.
redundancy groups is greater than zero.
Use the console port on the device that is the primary node to establish a CLI session.
12.
In the CLI session for the primary node device, issue the request chassis cluster failover
13.
command to fail over each redundancy group that has an ID number greater than
zero.
For example:
admin@cluster> request chassis cluster failover redundancy-group 1 node 1
In the CLI session for the primary node device, issue the request system power off
14.
command to shut down the services gateway. This action causes redundancy group
0 to fail over onto the other services gateway, making it the active node in the cluster.
Repeat Step
6
to install MPCs in the powered-off services gateway.
15.
Repeat Step
7
to install MICs in the MPCs in the powered-off services gateway.
16.
Power on the services gateway and wait for it to finish starting.
17.
Issue the show chassis fpc pic-status command on each node to confirm that all
18.
cards are online and both services gateways are operating correctly. For example:
user@host> show chassis fpc pic-status
Slot 0
Online
PIC 0
Online
PIC 1
Online
PIC 2
Online
PIC 3
Online
Slot 1
Online
PIC 0
Online
PIC 1
Online
PIC 2
Online
PIC 3
Online
Slot 2
Online
PIC 0
Online
PIC 2
Online
Issue the show chassis cluster status command to make sure that the priority for all
19.
redundancy groups is greater than zero.
Installing an SRX5400 Services Gateway MPC on page 122
Installing an SRX5400 Services Gateway MIC on page 126
Removing an SRX5400 Services Gateway Network Cable on page 130
Installing an SRX5400 Services Gateway Network Cable on page 130
Chapter 13: Replacing SRX5400 Services Gateway Hardware Components
SPU Flow
SPU Flow
SRX5k IOC II
2x 40GE QSFP+
10x 10GE SFP+
SRX5k SPC II
SPU Cp
SPU Flow
SPU Flow
SPU Flow
SRX5k SPC II
SPU Flow
SPU Flow
SPU Flow
SPU Flow
SRX5k IOC II
2x 40GE QSFP+
10x 10GE SFP+
129

Advertisement

Table of Contents
loading