Srx5400 Services Gateway Installation Safety Guidelines And Warnings; Chassis Lifting Guidelines; Installation Instructions Warning; Rack-Mounting Requirements And Warnings - Juniper SRX5400 Hardware Manual

Services gateway
Hide thumbs Also See for SRX5400:
Table of Contents

Advertisement

Related
Documentation

SRX5400 Services Gateway Installation Safety Guidelines and Warnings

Chassis Lifting Guidelines

Copyright © 2014, Juniper Networks, Inc.
extinguishers is monoammonium phosphate, which is very sticky and difficult to clean.
In addition, in minute amounts of moisture, monoammonium phosphate can become
highly corrosive and corrodes most metals.
Any equipment in a room in which a chemical fire extinguisher has been discharged is
subject to premature failure and unreliable operation. The equipment is considered to
be irreparably damaged.
NOTE:
To keep warranties effective, do not use a dry chemical fire extinguisher
to control a fire at or near a Juniper Networks services gateway. If a dry
chemical fire extinguisher is used, the unit is no longer eligible for coverage
under a service agreement.
We recommend that you dispose of any irreparably damaged equipment in an
environmentally responsible manner.
Qualified Personnel Warning on page 152
Restricted Access Area Warning on page 153
SRX5400 Services Gateway General Safety Guidelines and Warnings on page 151
SRX5400 Services Gateway Definition of Safety Warning Levels on page 149
Preventing Electrostatic Discharge Damage to the SRX5400 Services Gateway on
page 155
Chassis Lifting Guidelines on page 157
Installation Instructions Warning on page 158
Rack-Mounting Requirements and Warnings on page 159
Ramp Warning on page 162
The weight of a fully configured chassis is about 220 lb (100 kg). Observe these guidelines
for lifting and moving the services gateway:
Before moving the services gateway, check the Site Preparation Checklist to verify that
the intended site meets the specified power, environmental, and clearance
requirements.
Do not attempt to lift a fully configured services gateway by yourself. Using a mechanical
lift to maneuver the services gateway into a rack is recommended. If a lift cannot be
used, a minimum of three people are required to lift the services gateway, and you
must remove components from the chassis before lifting.
Appendix A: Safety and Regulatory Compliance Information