Troubleshooting SRX5400 Services MICs

Problem
Solution
Related
Documentation

Troubleshooting SRX5400 Services Gateway SPCs

Problem
Solution
Copyright © 2014, Juniper Networks, Inc.
Chapter 12: Troubleshooting the SRX5400 Services Gateway Hardware Components
Troubleshooting the SRX5400 Services Gateway with the Craft Interface LEDs on
page 94
Troubleshooting the SRX5400 Services Gateway with Alarm Relay Contacts on page 94
Troubleshooting the SRX5400 Services Gateway with the Component LEDs on page 95
The MICs are not functioning normally.
Check the status of each port on a MIC by looking at the LED located on the MIC
faceplate.
Check the status of a port module by issuing the
command. The MIC slots in the MPC are numbered from
user@host> show chassis fpc pic-status
Slot 0
Online
PIC 0
Online
PIC 1
Online
PIC 2
Online
PIC 3
Online
Slot 1
Online
PIC 0
Online
PIC 1
Online
PIC 2
Online
PIC 3
Online
Slot 2
Online
PIC 0
Online
PIC 2
Online
For further description of the output from the command, see Junos OS System Basics
and Services Command Reference at
Troubleshooting the SRX5400 Services Gateway with the Junos OS CLI on page 93
Troubleshooting the SRX5400 Services Gateway with the Craft Interface LEDs on
page 94
Troubleshooting the SRX5400 Services Gateway with Chassis and Interface Alarm
Messages on page 94
Troubleshooting the SRX5400 Services Gateway with Alarm Relay Contacts on page 94
A Services Processing Card (SPC) is not functioning normally.
Make sure the SPC is properly seated in the midplane. Check that each ejector handle
has been turned clockwise and is tight.
Issue the CLI
show chassis fpc
shown in the sample output, the value Online in the column labeled State indicates
that the SPC is functioning normally:
show chassis fpc pic-status
SRX5k SPC II
SPU Cp
SPU Flow
SPU Flow
SPU Flow
SRX5k SPC II
SPU Flow
SPU Flow
SPU Flow
SPU Flow
SRX5k IOC II
2x 40GE QSFP+
10x 10GE SFP+
www.juniper.net/techpubs/
command to check the status of installed SPCs. As
CLI
0
through
1
:
.
99

Advertisement

Table of Contents
loading

Table of Contents