Troubleshooting The Srx5400 Services Gateway With Alarm Relay Contacts - Juniper SRX5400 Hardware Manual

Services gateway
Hide thumbs Also See for SRX5400:
Table of Contents

Advertisement

SRX5400 Services Gateway Hardware Guide
Troubleshooting the SRX5400 Services Gateway with Chassis and Interface Alarm
Messages
Related
Documentation

Troubleshooting the SRX5400 Services Gateway with Alarm Relay Contacts

Related
Documentation
Troubleshooting the SRX5400 Services Gateway with the Craft Interface LEDs
94
Troubleshooting the SRX5400 Services Gateway with the Craft Interface LEDs on
page 94
Troubleshooting the SRX5400 Services Gateway with the Component LEDs on page 95
When the Routing Engine detects an alarm condition, it lights the major or minor alarm
LED on the craft interface as appropriate. To view a more detailed description of the
alarm cause, issue the
show chassis alarms
user@host> show chassis alarms
There are two classes of alarm messages:
Chassis alarms—Indicate a problem with a chassis component such as the cooling
system or power supplies.
Interface alarms—Indicate a problem with a specific network interface.
Troubleshooting the SRX5400 Services Gateway with the Junos OS CLI on page 93
Troubleshooting the SRX5400 Services Gateway with Alarm Relay Contacts on page 94
Troubleshooting the SRX5400 Services Gateway with the Craft Interface LEDs on
page 94
Troubleshooting the SRX5400 Services Gateway with the Component LEDs on page 95
The craft interface has two alarm relay contacts for connecting the services gateway to
external alarm devices. Whenever a system condition triggers either the major or minor
alarm on the craft interface, the alarm relay contacts are also activated. The alarm relay
contacts are located on the upper right of the craft interface.
Troubleshooting the SRX5400 Services Gateway with the Junos OS CLI on page 93
Troubleshooting the SRX5400 Services Gateway with Chassis and Interface Alarm
Messages on page 94
Troubleshooting the SRX5400 Services Gateway with the Craft Interface LEDs on
page 94
Troubleshooting the SRX5400 Services Gateway with the Component LEDs on page 95
The craft interface is the panel on the front of the services gateway located above the
card cage that contains LEDs and buttons that allow you to troubleshoot the device.
CLI command:
Copyright © 2014, Juniper Networks, Inc.