Install the Services Gateway Without a Mechanical Lift

Reinstall Components

12
Lifting the chassis and mounting it in a rack requires at least two people. The empty
chassis weighs approximately 65.5 lb (29.7 kg).
Ensure that the rack is in its permanent location and is secured to the building.
1.
Position the chassis in front of the rack or cabinet, centering it in front of the mounting
2.
shelf. Use a pallet jack if one is available.
With one person on each side, hold onto the bottom of the chassis and carefully lift
3.
it onto the small mounting shelf. See
Figure 7: Lift the Services Gateway into the Rack
5
4
3
2
1
0
1
0
Slide the chassis onto the mounting shelf until the mounting brackets contact the
4.
rack rails. The shelf ensures that the holes in the mounting brackets and the
front-mounting flanges of the chassis align with the holes in the rack rails.
To install the chassis in an open-frame rack, install a mounting screw into each of the
5.
open mounting holes aligned with the rack, starting from the bottom.
Visually inspect the alignment of the chassis. If the chassis is installed properly in the
6.
rack, all the mounting screws on one side of the rack should be aligned with the
mounting screws on the opposite side and the chassis should be level.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect
1.
the strap to one of the ESD points on the chassis. For more information about ESD,
see the SRX5600 Services Gateway Hardware Documentation at
www.juniper.net/techpubs/