Installing an SRX5400 Services Gateway AC Power Supply

138
NOTE:
After powering off a power supply, wait at least 60 seconds before
turning it back on.
To remove an AC power supply (see
Switch off the dedicated facility circuit breaker for the power supply, and remove the
1.
power cord from the AC power source. Follow the ESD and disconnection instructions
for your site.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect
2.
the strap to one of the ESD points on the chassis.
Move the AC switch next to the appliance inlet on the power supply to the off
3.
position (
).
O
Unscrew the captive screws on the bottom edge of the power supply.
4.
Remove the power cord from the power supply.
5.
Pull the power supply straight out of the chassis.
6.
Figure 57: Removing an AC Power Supply
To install an AC power supply (see
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect
1.
the strap to one of the ESD points on the chassis.
Move the AC switch next to the appliance inlet on the power supply to the off
2.
position (
O
).
Using both hands, slide the power supply straight into the chassis until the power
3.
supply is fully seated in the chassis slot. The power supply faceplate should be flush
with any adjacent power supply faceplate (see
Tighten both captive screws at the bottom of the power supply.
4.
Figure 57 on page
138):
Figure 58 on page
139):
Figure 58 on page
Copyright © 2014, Juniper Networks, Inc.
139).