Spacing of Rack Mounting Bracket Holes for the SRX5400 Services Gateway
Related
Documentation
38
With the use of adapters or approved wing devices to narrow the opening between the
rails, the services gateway can fit into a 600-mm-wide rack, as defined in the four-part
Equipment Engineering (EE); European telecommunications standard for equipment practice
(document numbers ETS 300 119-1 through 119-4) published by the European
Telecommunications Standards Institute (
Observe these guidelines:
The rack must have sufficient vertical usable space to accommodate the height of the
services gateway: 14.0 in. (35.6 cm) high (approximately 5 U). You can stack eight
services gateways in a rack that is at least 48 U (89.3 in. or 2.24 m) in height if it has a
1 in cap between.
NOTE:
A
U
is the standard rack unit defined in Cabinets, Racks, Panels, and
Associated Equipment.
The location of the rack must provide sufficient space to accommodate the depth of
the services gateway. The chassis is 24.5 in. (62.2 cm) deep.
The rack must be strong enough to support the weight of the fully configured device,
up to 220 lb (100 kg). If you stack five fully configured devices in one rack, it must be
capable of supporting up to 1100 lb (500 kg).
Overview of Installing the SRX5400 Services Gateway on page 33
Site Preparation Checklist for the SRX5400 Services Gateway on page 35
Spacing of Rack Mounting Bracket Holes for the SRX5400 Services Gateway on page 38
Connection to Building Structure for the SRX5400 Services Gateway Rack on page 39
Clearance Requirements for SRX5400 Services Gateway Airflow and Hardware
Maintenance on page 39
The services gateway can be mounted in any rack that provides holes or hole patterns
spaced at 1 U (1.75 in.) increments. The mounting brackets used to attach the chassis to
a rack are designed to fasten to holes spaced at those distances.
Overview of Installing the SRX5400 Services Gateway on page 33
SRX5400 Services Gateway Rack Size and Strength Requirements on page 37
Connection to Building Structure for the SRX5400 Services Gateway Rack on page 39
Clearance Requirements for SRX5400 Services Gateway Airflow and Hardware
Maintenance on page 39
).
http://www.etsi.org