Testing - Toro Z Master G3 3000 Series Service Manual

Table of Contents

Advertisement

ELECTRICAL

Testing

1. Disconnect the relay from the harness.
2. Verify the coil resistance between terminals 85 and
86 with a multimeter (ohms setting). Resistance
should be from 70 to 90 ohms. There should be
continuity between terminals 87a and 30.
3. Connect multimeter (ohms setting) leads to relay
terminals 30 and 87. Ground terminal 86 and apply
+12 VDC to 85. The relay should make and break
continuity between terminals 30 and 87 when 12
VDC is applied and removed from terminal 85.
4. Connect multimeter (ohms setting) leads to relay
terminals 30 and 87a. Apply +12 VDC to terminal
85. With terminal 86 still grounded, the relay should
break and make continuity between terminals 30
and 87a as 12 VDC is applied and removed from
7
terminal.
7-2
Fig. 485
relay pin diagram
5. Disconnect voltage and multimeter leads from relay
terminals (Fig. 486).
Toro Z Master G3 3000/5000/6000 Series Service Manual
Fig. 486
xl relay

Hide quick links: