Check the hydraulic fluid level:
49. Raise the seat up.
50. Clean the area around the dipsticks of UHT reser-
voirs (Fig. 327).
51. Remove one dipstick from the UHT reservoir (Fig.
327).
52. Wipe the dipstick off and thread the dipstick into the
reservoir.
53. Remove the dipstick and look at the metal end (Fig.
327). The level needs to be within knurled section.
If oil level is low, slowly pour only enough oil into
the UHT reservoir to raise the level to the knurled
section.
Important: Do not overfill the UHT with oil as dam-
age may occur. Do not run the machine with oil
below the knurled section or damage may occur.
54. Install the dipstick. Repeat for opposite side.
55. Operate the machine to bring transmissions to
normal temperature.
56. Position the machine on a level surface.
57. Disengage the PTO, move the motion control levers
to the neutral locked position and set the parking
brake.
Toro Z Master G3 3000/5000/6000 Series Service Manual
HYDRAULIC SYSTEM
58. Stop the engine, remove the key, and wait for all
moving parts to stop before leaving the operating
position.
59. Allow the engine and hydraulic system to cool for ten
minutes. Recheck oil level and top off as required
(Fig. 327).
A
B
Fig. 327
This is a top view (under seat)
A. Oil level within
knurled section
fig. 76 G008967
B. Dipstick locations
5-19