Electrical; General; Relay; Purpose - Toro Z Master G3 3000 Series Service Manual

Table of Contents

Advertisement

General

Note: Interactive Electrical Troubleshooting DVD,
Part #492-9193 is also available.

Relay

Purpose

There is one relay on this machine.
1. Start Relay: Functions as an electronic switch.
Once the safety connections are met, the relay will
activate completing the circuit to the starter solenoid.

Location

The relay is located on the frame, right side of the
engine, in front of the battery (Fig. 483).
Fig. 483
Toro Z Master G3 3000/5000/6000 Series Service Manual
How It Works
A relay is an electrically actuated switch.
1. Coil: Terminals 85 and 86 are connected to a coil.
Applying 12 volts to these terminals energizes the
coil turning it into an electromagnet.
2. Switch: Terminals 30, 87 and 87a are actually
part of a single pole, double throw (SPDT) switch.
Terminal 30 is the common lead. The switch is
spring loaded so that 30 and 87a are connected
when the coil is not energized. When the coil is
energized, the switch is "thrown" and terminals 30
and 87 are connected (Fig. 484).
DSCN-0008

ELECTRICAL

Fig. 484
DSC-2517a
7
7-1

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents