Install the SCM according to
When the SCM first powers up it performs a self-test. All LEDs illuminate red, then yellow, then
green. Next the LEDs may cycle from top to bottom several more times during the self-test.
When the self-test is complete, all LEDs on all modules reflect their true status. Refer to
Panel LEDs"
on page 54.
NOTICE
If a hardware failure is detected at startup, the LEDs flash in a
circular pattern.
If only A or B power is supplied, the SCM reports a MINOR alarm
for single power failure. If single-feed power is supplied, the power
cabling should be connected to both A and B terminals.
NOTE
To test the LEDs, press and hold the Alarm Cut Off (
After three seconds, all LEDs on the chassis should turn yellow.
61184500L1-5L
Figure
20.
1. Open latch
2. Align module with
guide groove;
push firmly until
seated

Figure 20. Module Insertion Diagram

3. Close latch
) button.
ACO
SCM Installation
"Front