Account Lock-Out Options Menu
Main\System Controller\Provisioning\System Administration\Security Administration\Security
Account Lock-Out Options
The Account Lock-Out Options menu
TID: HSV00001
Unacknowledged Alarms:
Table 69
lists the Account Lock-Out Options.
Option
Description
1
Lock-Out User on
Login Failure
2
Enable Lock-Out
Alarm
3
INDEFINITE LOCK-
OUT On Login Failure
4
Number of Login
Failure Before
Lock-Out
5
Lock-Out Duration
in Minutes
61184500L1-5L
(Figure
OPTI-6100 System
Account Lock-Out Options
1.
Lock-Out User on Login Failure
2.
Enable Lock-Out Alarm
3.
INDEFINITE LOCK-OUT On Login Failure
4.
Number of Login Failure Before Lock-Out
5.
Lock-Out Duration in Minutes
Selection :
'?' - System Help Screen
Figure 77. Account Lock-Out Options Menu
Table 69. Account Lock-Out Options
Function
This option toggles an account lockout for login failures.
♦
Yes: Options 2–5 in this menu are active.
No: No lock-out on login failure (default). Options 2–5 are ignored.
♦
This option toggles the sending of an alarm when an account is
locked out.
♦
Yes: An account lock-out raises an alarm (default).
No: No alarm on account lock-out.
♦
This option toggles the account lock-out duration.
Yes: Lock-out remains in effect until an ADMIN-level user unlocks
♦
the affected account.
No: Lock-Out Duration in Minutes applies (default). See below.
♦
This option specifies the maximum number of login attempts allowed
before a lock-out occurs.
The valid range is 2–15 attempts, with a default of 5.
This option specifies the time a lock-out remains in effect.
The valid range is 1–60 minutes, with a default of 1.
Options\Account Lock-Out Options\
77) specifies the system response to a failed login.
OPTI-6100 Main Menu
MM/DD/YY hh:mm
MX Chassis:
1
: NO
: YES
: NO
: 5
: 1
141