ADTRAN OPTI-6100 Installation Manual page 36

Installation and turn-up practice
Hide thumbs Also See for OPTI-6100:
Table of Contents

Advertisement

OPTI-6100 Installation and Turn-Up Practice
CAUTION
!
Per GR-1089-CORE the OPTI-6100 is designed and intended for
installation as part of a Common Bonding Network (CBN).
The OPTI-6100 System is not designed nor intended for
installation as part of an Isolated Bonding Network (IBN).
The OPTI-6100 ground wire must be of equal or greater ampacity
than the wire(s) connected to the battery return. Per GR-1089-
CORE Section 9, the OPTI-6100 does not have an internal DC
connection between battery return and frame ground.
The OPTI-6100 can be installed in a DC-I (isolated) or DC-C
(common) installation. For installations where other cards or the
host system have internal connections between battery return
and frame ground, the OPTI-6100 system would be intended for
deployment only in a DC-C installation.
NOTE
The OPTI-6100 chassis 10/100Base-T Ethernet management
ports are classified as Type 2 or 4, as defined in Appendix B of GR-
1089-CORE Issue 4, and are suitable for connection to intra-
building or unexposed wiring or cabling only. Do not metallically
connect these ports to interfaces which connect to the Outside
Plant (OSP) or to the OSP wiring.
The 10/100Base-T Ethernet management ports are designed for
use as intrabuilding interfaces only (Type 2 or Type 4 ports as
described in GR-1089-CORE Issue 4) and require isolation from
exposed OSP cabling. The addition of Primary Protectors is not
sufficient protection in order to connect these interfaces
metallically to OSP wiring.
To meet NEBS compliance and to provide proper airflow through
the chassis, blank panels are required on unpopulated slots.
Current limiting protectors are not required.
The OPTI-6100 is designed to meet the following environmental classes:
ETSI EN 300 019-1-1 "Classification of environmental conditions; Storage," Class 1.2
ETSI EN 300 019-1-2 "Classification of environmental conditions; Transportation,"
Class 2.3
ETSI EN 300 019-1-3 "Classification of environmental conditions; Stationary use at
weatherprotected locations," Class 3.3
The equipment is designed to function without degradation during exposure to all test severities
per Class 019-1-3 3.3.
10
61184500L1-5L

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents