Table 147. Ds3M3T Provisioning Options - ADTRAN OPTI-6100 Installation Manual

Installation and turn-up practice
Hide thumbs Also See for OPTI-6100:
Table of Contents

Advertisement

Table 147
lists the minimum factory defaults and values that are loaded after installation and
self-test for the DS3M3T module.
Provisioning Options
Equipment Provisioned State
AINS Time
AINS Timer
Loopback Timeout
Loopback Timer
Facility #1–3 Provisioned State
Facility #1–3 DS3 Framing
Facility #1–3 Line Build Out
Facility #1–3 DS3 FEAC
Loopback Code Detection
Facility #1–3 Line Identification
Facility #1–3 Alarm Reporting
Board Operating Mode
PRI Clock Output to OMM
SEC Clock Output to OMM
1. Use Short for distances of less than 225 feet of 728A/734A coax, or 125 feet of 735A coax.
2. EC1 Operating Mode only
61184500L1-5L

Table 147. DS3M3T Provisioning Options

Settings
1 Minute to 96 Hours; 4:00 is the default
1 Minute to 96 Hours; 2:00 is the default
(enter text)
2
2
Tributary Module Installation and Turn-Up
IS
OOS-MA
OOS-MA UAS (default)
Enabled (default)
Disabled
Enabled
Disabled (default)
IS
OOS-MA
OOS-MA UAS (default)
Auto (default)
M13
CBIT
Unframed
Short
(default)
1
Long
Short, Low
Enabled
Disabled (default)
Enabled (default)
Disabled
DS3 (default)
EC1
Disabled (default)
Facility 1
Disabled (default)
Facility 1
285