OPTI-6100 Installation and Turn-Up Practice

SMX Chassis Alarm Connectors

Connect auxiliary alarm inputs to the wire-wrap pins in the lower right of the chassis rear panel
(Figure
16). There are three sets of pins labeled
pins for the RS-485 bus.
RS-485 (P8)
Auxiliary Inputs (P7)
The SMX chassis wire wrap pins are defined below.
RS-485 Connectors (P8) – Left to Right
IB_BUS_OUT– (RS-485 Bus)
IB_BUS_OUT+ (RS-485 Bus)
GND (Data Ground)
IB_BUS_IN– (RS-485 Bus)
IB_BUS_IN+ (RS-485 Bus)
GND (Data Ground)
FAN_ALM_B
FAN ALM_A
Visual Alarms (P15) – Left to Right
VIS_CRI_ALM_A Visual CRITICAL alarm
VIS_CRI_ALM_B Visual CRITICAL alarm
VIS_MAJ_ALM_A Visual MAJOR alarm
VIS_MAJ_ALM_B Visual MAJOR alarm
VIS_MIN_ALM_A Visual MINOR alarm
VIS_MIN_ALM_B Visual MINOR alarm
44
Figure 16. Auxiliary Pinouts – SMX Chassis
,
, and
AUX
ACO
FAN
P8
P15
P7
Auxiliary Inputs (P7) – Left to Right
ACO_IN_B Audible Alarm Cut-off
ACO_IN_A Audible Alarm Cut-off
AUX3_IN_B Alarm Input
AUX3_IN_A Alarm Input
AUX2_IN_B Alarm Input
AUX2_IN_A Alarm Input
AUX1_IN_B Alarm Input
AUX1_IN_A Alarm Input
Audible Alarms (P14) – Left to Right
AUD_CRI_ALM_A Audible CRITICAL alarm
AUD_CRI_ALM_B Audible CRITICAL alarm
AUD_MAJ_ALM_A Audible MAJOR alarm
AUD_MAJ_ALM_B Audible MAJOR alarm
AUD_MIN_ALM_A Audible MINOR alarm
AUD_MIN_ALM_B Audible MINOR alarm