Cross-Connect Module Installation; Figure 146. Ommxcv Module - ADTRAN OPTI-6100 Installation Manual

Installation and turn-up practice
Hide thumbs Also See for OPTI-6100:
Table of Contents

Advertisement

OPTI-6100 Installation and Turn-Up Practice

Cross-Connect Module Installation

Use this Installation and Turn-Up procedure for the OPTI-6100 Cross-Connect Module
(OMMXCV, P/N 1184536L1).
The OMMXCV module
capability within the chassis is required, but a high-speed network interface is not required.
The OMMXCV cross-connects VT and STS traffic between tributary modules, supporting any
valid VT1.5/STS-1/STS-3c combination. Up to 12×STS-1 paths can be mapped.
NOTICE
Electrostatic discharge (ESD) can damage electronic modules.
Before handling modules, wear an antistatic discharge wrist strap
to prevent damage to electronic components. Place modules in
antistatic packing material when transporting or storing. When
working on modules, always place them on an approved antistatic
mat that is electrically grounded.
Inspect all modules prior to installation. If a module has been
damaged during shipping, file a claim with the carrier and contact
ADTRAN Customer Support. Refer to
The OMMXCV module plugs directly into the MX or SMX chassis in either of the two HS slots
located directly in the center of the chassis, labeled
NOTE
The OMMXCV module is not supported in the LMX chassis.
246
(Figure
146) is used in place of an OMM module when cross-connect

Figure 146. OMMXCV Module

"Appendix D,
OMMXCV
1184536L1
STATUS
ALARM
ON LINE
TEST
and
HS1
HS2
Warranty".
on the bottom edge.
61184500L1-5L