Table 129. Omm12 Provisioning Options - ADTRAN OPTI-6100 Installation Manual

Installation and turn-up practice
Hide thumbs Also See for OPTI-6100:
Table of Contents

Advertisement

OPTI-6100 Installation and Turn-Up Practice
23. Repeat these steps to set the payload type and to map an STS to each equipped mid-speed
group. Remember to map both HS1 and HS2.
24. Press
to return to the Provisioning menu.
E
SC
Table 129
lists the minimum factory defaults and values that are loaded after installation and
self-test for the OMM12 modules.
Provisioning Options
Equipment Provisioned State
System Mode*
Facility Provisioned State
Clock Switch Mode
Clock Source
Clock Out
Clock Out Mode
Clock Output LBO
Clock Output Type
Clock Output Source
Clock Out Source Mapping
OC-N Transmit Sync Message
Receive Sync Message
Signal Degrade
Signal Fail
*= This option only applies to UPSR modules.
232

Table 129. OMM12 Provisioning Options

Settings
IS
OOS-MA
Terminal (default)
UPSR
IS
OOS-MA
Auto Switch PRI/SEC (default)
PRI Only
Refer to
"OMM Module Clock Source Settings"
Enable
Disable (default)
Dual Output from Chassis (default)
Single Output from Chassis
0
133 ft. (default)
134
266 ft.
267
399 ft.
DS1 SF (default)
DS1-ESF
Receive Fiber (default)
Internal Clock
Out PRI = PRI, Out SEC = SEC (default)
Out PRI & SEC = Clock Source
Derive From Source (default)
Don't Use
Enable (default)
Disable
10 E-5 (default)
10 E-6
10 E-7
10 E-3 (default)
10 E-4
OOS-MA UAS (default)
OOS-MA UAS (default)
SEC Only
on page 249.
400
533 ft.
534
655 ft.
Ext Clock In
Trib Module
Out PRI & SEC = PRI
Out PRI & SEC = SEC
10 E-8
10 E-9
10 E-5
61184500L1-5L