Table 131. Omm48 Provisioning Options - ADTRAN OPTI-6100 Installation Manual

Installation and turn-up practice
Hide thumbs Also See for OPTI-6100:
Table of Contents

Advertisement

20. From the Mapping menu, select the STS-1 or STS-3 to map, and press
Refer to
"Mapping Cross-Connects"
21. Press
to return to the Provisioning menu.
E
SC
Table 131
lists the minimum factory defaults and values that are loaded after installation and
self-test for the OMM48 modules.
Provisioning Options
System Mode
Equipment
Provisioned State
Facility
Provisioned State
Clock Switch Mode
Clock Source
Clock Out
Clock Out Mode
Clock Output LBO
Clock Output Type
Clock Output Source
Clock Out Source Mapping
OC-N Transmit Sync Message
Receive Sync Message
Signal Degrade
Signal Fail
61184500L1-5L
on page 337 for mapping instructions.

Table 131. OMM48 Provisioning Options

Settings
Terminal (default)
UPSR
IS
OOS-MA
IS
OOS-MA
Auto Switch PRI/SEC (default)
PRI Only
Refer to
"OMM Module Clock Source Settings"
Enable
Disable (default)
Dual Output from Chassis (default)
Single Output from Chassis
0
133 ft. (default)
134
266 ft.
267
399 ft.
DS1 SF (default)
DS1-ESF
Receive Fiber (default)
Internal Clock
Out PRI = PRI, Out SEC = SEC (default)
Out PRI & SEC = Clock Source
Derive From Source (default)
Don't Use
Enable (default)
Disable
10 E-5 (default)
10 E-6
10 E-7
10 E-3 (default)
10 E-4
OMM Module Installation and Turn-Up
.
E
NTER
OOS-MA UAS (default)
OOS-MA UAS (default)
SEC Only
on page 249.
400
533 ft.
534
655 ft.
Ext Clock In
Trib Module
Out PRI & SEC = PRI
Out PRI & SEC = SEC
10 E-8
10 E-9
10 E-5
239

Hide quick links: