Table 160. Tram3 Provisioning Options - ADTRAN OPTI-6100 Installation Manual

Installation and turn-up practice
Hide thumbs Also See for OPTI-6100:
Table of Contents

Advertisement

Table 160
lists the minimum factory defaults and values that are loaded after installation and
self-test for the TRAM3 module.
Provisioning Options
Equipment Provisioned State
Facility #1 – 3 Provisioned State
Board Operating Mode
AINS Time
AINS Timer
DS3 Framing
Line Build Out
Mapping
2
1. Use Short for distances of less than 225 feet of 728A/734A coax, or 125 feet of 735A coax.
2. The specific mapping of the STS VT Group-VT is based on M13 or GR253 mapping, entirely provisioned on the
OMM modules.
Table 143
61184500L1-5L

Table 160. TRAM3 Provisioning Options

Settings
IS
OOS-MA
OOS-MA UAS (default)
IS
OOS-MA
OOS-MA UAS (default)
DS3 (default)
EC1
1 Minute to 96 Hours; 4:00 is the default
Enabled
Disabled (default)
Cbit
M13 (default)
Short
Long
GR-253
M13 (default)
on page 273 shows VT mapping to DS1 ports on the transmux modules.
Tributary Module Installation and Turn-Up
1
(default)
323