Table 160
lists the minimum factory defaults and values that are loaded after installation and
self-test for the TRAM3 module.
Provisioning Options
Equipment Provisioned State
Facility #1 – 3 Provisioned State
Board Operating Mode
AINS Time
AINS Timer
DS3 Framing
Line Build Out
Mapping
2
1. Use Short for distances of less than 225 feet of 728A/734A coax, or 125 feet of 735A coax.
2. The specific mapping of the STS VT Group-VT is based on M13 or GR253 mapping, entirely provisioned on the
OMM modules.
Table 143
61184500L1-5L
Table 160. TRAM3 Provisioning Options
Settings
♦
IS
OOS-MA
♦
OOS-MA UAS (default)
♦
IS
♦
♦
OOS-MA
OOS-MA UAS (default)
♦
DS3 (default)
♦
EC1
♦
1 Minute to 96 Hours; 4:00 is the default
♦
Enabled
♦
Disabled (default)
♦
Cbit
M13 (default)
♦
♦
Short
♦
Long
GR-253
♦
M13 (default)
♦
on page 273 shows VT mapping to DS1 ports on the transmux modules.
Tributary Module Installation and Turn-Up
1
(default)
323