Figure 126. Fanm Pwr A Fail Menu; Table 117. Fanm Pwr A / B Fail Menu Options - ADTRAN OPTI-6100 Installation Manual

Installation and turn-up practice
Hide thumbs Also See for OPTI-6100:
Table of Contents

Advertisement

OPTI-6100 Installation and Turn-Up Practice
FANM Pwr A/B Fail Menu
Main\System Alarms\User-Definable Alarms\Environmental Alarms\Auxiliary Fan Alarms\Auxiliary Fan Alarm
FANM Pwr A/B Fail
Use the FANM Pwr A/B Fail menus
TID: HSV00001
Unacknowledged Alarms: None
Selection :
Table 117
lists the options in the FANM Pwr A/B Fail menus.
Option
Description
1
FANM Pwr A/B Fail
Description
2
FANM Pwr A/B Fail
Level
3
FANM Pwr A/B Fail
AID Index
4
FANM Pwr A/B Fail
Condition Code
* = FANM Pwr B Fail Level is Minor if Fan Power A is functioning properly. If Fan Power A fails, FANM Pwr B Fail
Level is reported as Critical.
212
(Figure
OPTI-6100 System
FANM Pwr A Fail
1.
FANM Pwr A Fail Description
2.
FANM Pwr A Fail Level
3.
FANM Pwr A Fail AID Index
4.
FANM Pwr A Fail Condition Code
'?' - System Help Screen

Figure 126. FANM Pwr A Fail Menu

Table 117. FANM Pwr A / B Fail Menu Options

Function
This option sets the fan power A/B failure alarm description.
The defaults are
This option sets the alarm level reported for fan power A/B failures.
The available options are as follows:
Info
Alert
Minor* (default)
Major
Critical
This option sets the AID Index for the fan power A/B failure alarms.
The valid range is 1–64. The defaults are 26 and 27, respectively.
This option sets a TL1 Condition Code for fan power A/B failure alarms.
The defaults are
126) to provision fan power A and B alarm inputs.
: FANM Pwr A Fail
: MINOR
: 26
: FANM-PWRPRI
and
FANM Pwr A Fail
and
FANM-PWRPRI
FANM-PWRSEC
Inputs\FANM Pwr A/B Fail\
MM/DD/YY hh:mm
MX Chassis:
1
.
FANM Pwr B Fail
.
61184500L1-5L

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents