Fiber Connection And Routing; Module Insertion; Figure 138. Omm3 Module Insertion Diagram - ADTRAN OPTI-6100 Installation Manual

Installation and turn-up practice
Hide thumbs Also See for OPTI-6100:
Table of Contents

Advertisement

OPTI-6100 Installation and Turn-Up Practice

Fiber Connection and Routing

Identify the fiber conductors to be terminated on the OMM module, and insert the connectors
into the
or
jacks as appropriate. See
IN
OUT
NOTE
The OMM3SC and OMM3SR modules only terminate one fiber each.

Module Insertion

NOTE
If present, remove the HS Module Blank (P/N 1184506L1) from the
appropriate slot of the OPTI-6100 chassis.
Install the OMM module according to
NOTE
Route the fiber conductors along the chassis fiber tray.
226
Figure
1. Open latch

Figure 138. OMM3 Module Insertion Diagram

Figure 137
on page 224 (left) for fiber routing.
138.
3. Close latch
2. Align module with
guide groove;
push firmly until
seated
61184500L1-5L