OPTI-6100 Installation and Turn-Up Practice
Table 105
lists the options in the System Alarms menu.
Option
Description
1
Shelf Alarm Status
2
Alarm Logs
3
User-Definable Alarms
4
Alarm Chronology
5
Remote RT Alarm Reporting
6
Acknowledge RT Alarm Status
7
Alarm Contact Definition
8
Alarm Enable Disable
198

Table 105. System Alarms Menu Options

Function
This option displays the
page 199.
This option displays the
This option displays the
on page 201.
This option specifies the display order of alarms.
Select Ascending (default) or Descending.
If Mount Location is Central Office, this option enables/
disables alarm reporting for any RT chassis on the
network. When applicable, the default is Enabled.
If Mount Location is Subtended, this option reads
Not Applicable
Refer to
This option is only visible if Remote RT Alarm Reporting
(above) is a selectable option. Select this option to
acknowledge active alarms on a remote terminal.
This option sets the Alarm Contact Definition. The
available options are as follows:
Normally Open: Open alarm contacts are not reported
as alarms (default). Closed contacts are reported.
Normally Closed: Closed alarm contacts are not
reported as alarms. Open contacts are reported.
This option displays the
Menu"
"Shelf Alarm Status Screen"
"Alarm Log Screen"
"User-Definable Alarms Menu"
, and cannot be selected.
"Network Management Menu"
"Alarm Enable Disable Interface
on page 216.
on
on page 200.
on page 85.