ASCOM Ascotel 2025 System Manual page 595

Isdn telecommunications system
Table of Contents

Advertisement

ascom
Ascotel 2025/2045/2065
System Configuration
Tab. 2.288: External remote control: System configuration
Parameter
Password
External remote control
(ERC)
Internal digit barring
Remote control
Direct dial number
CDE destination
Reference to other Features
Features:
• "Remote Controlling Features from within the System", Page 2.414
2.418
Features
Parameter value
6 digits exactly with digits (0 to 9)
Enabled
Selects the internal digit barring for
switch position 1 to 3 of switch
group 1
Enabled
<ERC DDI number>
ERC
Remarks
Adjustable throughout the system at the
attendant authorization (also with the
System Assistant of the Office 45)
Initialization values:
• Digit barring settings:
8/8/8 (2025/2045)
16/16/16 (/2065)
• Digit barring 8/16: *85, *75, #75 barred
Subscriber-specific (enable remote control
of the subscriber's terminal)
Create DDI number for ERC and link with
CDE
Can only be entered once a valid pass-
word has been entered
HBT_20321104_02/B0_en