ASCOM Ascotel 2025 System Manual page 434

Isdn telecommunications system
Table of Contents

Advertisement

• Caller identification 1, outgoing:
On the OCL report at the gateway / transit PINX: The subscriber call number
valid within the network is entered here.
On the OCL report at the source PINX no number is entered in this field.
• Caller identification 2, outgoing:
On the OCL report at the source / transit PINX: The subscriber call number valid
within the PISN is entered here.
On the OCL report at the gateway PINX: The subscriber's DDI number is
entered here.
On a stand-alone PBX the entries are output analogue to a source PINX.
PBX
DDI:54
Fig. 2.134: Caller identification outgoing
HBT_20321104_02/B0_en
032 624 33 00
032 624 33 99
haz0607aaena0
ascom
Region 60
PINX 1
032 624 24 00
032 624 24 99
Region 50
PINX 2
Ascotel 2025/2045/2065
DDI 53 — > Subscriber 50 300
Caller: ID1: 50 300
Call
Logging
Caller: ID2: 53
PC
Caller: ID1: –
Call
Logging
Caller: ID2: 50 300
PC
Subscriber Nr. 300