ASCOM Ascotel 2025 System Manual page 460

Isdn telecommunications system
Table of Contents

Advertisement

PC2 Format
This format is an extension of the PC1 format. Here the cost centre number is also
output as a separate field, along with the DDI number.
Format Structure
Tab. 2.114: PC2 format
Data field, meaning
Start of data record
Subscriber number
Cost centre number
Sort character
Date of start of connection
Time of start of connection
Duration of connection
Primary channel group / trunk card number / net-
work interface number
1)
Direct dial number
Number of metering pulses
2)
Call number dialled
Serial number
Carriage Return
Line Feed
1)
This is the direct dial number that is displayed as the CLIP to an external call partner.
2)
If "Data protection" is configured, the last 4 digits of the number are replaced by the space character
"SP".
HBT_20321104_02/B0_en
ascom
Ascotel 2025/2045/2065
Structure
HT
ttttt
kkkkkkkkk
oo
yymmdd
hh:mm
hhHmmMss
cbbpp
ddddddddddd
iiiii
zzzzzzzzzzzzzzzzzzzz
llll
CR
LF
Format
Length Offset
1
|-
SP
5
|-
SP
9
00
-|
2
00
-|
6
00
-|
5
00
-|
8
00
-|
5
|-
SP
11
00
-|
5
|-
SP
20
00
-|
4
1
1
Call Logging (CL)
0
1
7
17
20
27
33
42
48
60
66
87
91
92
2.283