The following parameters need to be selected or entered in the Fault & Mainte-
nance Manager for each of the two external signal destinations:
• Call number of the external signal destination (possibly as a route selection)
Possible external signal destinations include:
– Ordinary exchange output (route 3 is used)
– Route selection
– Cost centre selection (route 3)
After initialization, the call charges are allocated to cost centre 100.
• IP address of the PC if the PBX is to connect with the PC via an ISDN gateway.
If the PBX is to connect with the PC without ISDN gateway, the "IP address"
entry should remain empty.
• TCP port number (the initialization value is 1062; if the value is changed in the
SEM, it will have to be altered accordingly on the PBX side.)
• User name and password of the dial-up networking of the PC or ISDN gateway,
to gain access via the TA or the ISDN gateway to the PC with the SEM.
See also:
For information on dial-up networking configuration on the PC, see
"Settings on the PC", Page 5.8.
Other necessary Configurations
The following parameters must also be configured.
• In the Fault & Maintenance Manager:
System ID of the PBX. This is important so that the PBX can be identified by the
SEM. The system ID must match the system ID stored in the AIMS Shell. In the
system ID you can store a serial number or the DDI number for the remote
maintenance of the PBX (20 digits).
• In the Configuration Manager:
Route 3 must be allocated trunk groups with digital network interfaces
("Routes" setting).
HBT_20321104_07/B0_en
ascom
Ascotel 2025/2045/2065
Operations Supervision
7.47