Tab. 4.34:
Power available depending on the line length
Loop resistance R
20
Power available
2620
P
. (mW)
max
Length (m) with:
0.4 mm wire ø
71
0.5 mm wire ø
111
0.6 mm wire ø
160
Admissible range for 2 terminals on the AD2 bus with an assumed max. line length of 700 m
Automatic Measuring of Line Length
If all of a terminal's LEDs are lit (e.g. team keys) and at the same time the terminal
rings with maximum volume, the power input is maximum. The power supply can
become critical depending on the line length:
• When connecting an Office terminal to the AD2 bus, the power input is auto-
matically determined, whereby all devices (Office XX, EKP, AKB) connected to
the bus are taken into account.
• The terminal displays the message "Power critical" if the power input is not
enough. The line length is precisely calculated at about 150 m and based on a
wire diameter of 0.5 mm.
• The text message can be deleted and the terminal can be operated nevertheless
under normal conditions.
HBT_20321104_04/B0_en
40
60
80
100
2492
2364
2236
2108
142
213
284
356
222
333
444
556
320
480
640
800
ascom
120
140
160
180
1980
1852
1724
1596
427
498
569
640
667
778
889
1000
960
1120
1200
1200
Ascotel 2025/2045/2065
200
220
240
260
1459
1343
1245
1160
711
782
853
924
1111
1200
1200
1200
1200
1200
1200
1200
Cabling Interfaces
280
300
1086
1021
996
1000
1200
1200
1200
1200
4.59