Tab. 7.24:
Error message during software version transfer (version transfer configuration
data organization OIM)
Identification
Error description
402
Version transfer not possible due to incor-
rect mainboard
403
Version transfer not possible: Version of
the PBX software used to create the con-
figuration data is more recent than the
software currently on the PBX
404
Version transfer not possible: Country or
sales channel on the PBX (EIM card) does
not match information in the configura-
tion data on the Flash (e.g. country code in
Flash memory is CH and in the software it
is D)
405
Version transfer not possible:
Software release unknown.
Note:
If error codes 405 to 404 occur, the system will halt the startup. Proceed-
ing with the startup results in a system initialization.
Tab. 7.25:
Self-test error messages (system unable to run)
Identification
Error description
500
Program checksum incorrect
503
Too many system restarts
504
Program error after startup
505
DRAM SIMM defective
Tab. 7.26:
Self-test error messages in Xmodem mode (system unable to run)
Identification
Error description
601
XMODEM transfer aborted
602
XMODEM transfer rejected
HBT_20321104_07/B0_en
ascom
Ascotel 2025/2045/2065
Error handling
• Replace mainboard
• Load new software onto mainboard
• Fit a different mainboard with correct
country or distribution channel
• Load new software onto mainboard
Error handling
• Load correct software onto the PBX
• Replace mainboard
• Replace mainboard or RAM card
• Replace mainboard
Error handling
• Retry transfer
• Ensure that correct file is being transmit-
ted