Settings on the Source PINX (PINX 1):
• Subscriber configuration:
A permanent CLIP number is configured for internal subscribers in Geneva,
which is transmitted unchanged along with each outgoing call to the public
network.
• Least Cost Routing:
The initial digits of the numbers within the Zurich local rate zone are entered
in the LCR table and allocated a route via the routing and network operator
table(see also from Page 2.155).
• Setting up routes:
– All calls sent to the public network via Zurich are routed via a separate route.
Its configuration must
include the setting NPI = E.164 so that PINX 2 recognizes a call as external
and routes it accordingly.
– All calls addressed to PINX 2 subscribers in Zurich are routed via another
route whose configuration contains the setting NPI = PNP.
– Both routes can be allocated to the same trunk group.
• Trunk group settings:
– Network = Private
– Protocol = PSS1
– Automatic CLIP = Yes