ASCOM Ascotel 2025 System Manual page 1068

Isdn telecommunications system
Table of Contents

Advertisement

Tab. 7.18:
The displayed data and what it means
Display
Description
BCS: xxxxx
Number of existing BCS references
CC: xxxxx
Number of existing call controls
SUBS: xxxx
Number of subscribers in the system
NSUB: xxxx
Number of PISN subscribers in the sys-
tem
LINE: xxxx
Number of lines in the system
DIST: xxxx
Number of call distributions in the sys-
tem
DDIN: xxxx
Number of DDI numbers in the system DDIN: 0000
ABB: xxxx
Number of abbreviated dialling num-
bers in the system
System Failures Menu Item
Tab. 7.19:
System failures display
== SYSTEM FAILURES
W 15.09.00
13:32
W 06.12.00
13:32
The system's last 80 system failures (resets) are displayed. The resets are incre-
mented in the counter in the top right (0...255).
Significance of the display: Error type W = restart (watchdog), date, time
When printing, only the last 4 addresses are printed out.
Power Failures Menu Item
Tab. 7.20:
Power failures display
== POWER FAILURES
01.12.98
16:13
Only the restart time is recorded.
HBT_20321104_07/B0_en
Normal value /
idle state
BCS: 00000
CC: 00000
SUBS: 0000
NSUB: 0000
LINE: 0000
DIST: 0000
ABB: 1000
011A59F2,
011A5A8C,
011A59F7
011A5A82
ascom
Ascotel 2025/2045/2065
Note
Each active connection needs 2
BCS references
For each BCS reference there is
one or more CC
0000: No ports busy
0000: No PISN SC in the system
0000: No lines defined
0000: No call distribution
defined
0000: No DDI numbers defined
1000: Initialization value
unchanged
01156FFE
01156FF1
Operations Supervision
52
7.69

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ascotel 2045Ascotel 2065

Table of Contents